Grease separator in a restaurant in Poland: when it is required, the water utility contract and grease collection

Does a restaurant have to have a grease separator? We break the duty down by provision: art. 6, 9, 10 and 28 of the act on collective water supply, the wastewater discharge regulation, the role of the water utility contract and MPWiK in Warsaw, the distance from windows (with a caveat on the status of the former § 38), emptying and waste code 19 08 09, penalties, a worked cost example and a checklist.

Published
23 min read4647 words
Aura editorialAuthor

Key takeaways

  • We did not find a provision that outright orders every restaurant to have a separator; the pretreatment duty comes from art. 10 point 2 of the act for an industrial wastewater supplier and from the terms of the water utility contract.
  • Discharging wastewater requires a written contract (art. 6 para. 1); discharging without one carries restriction of liberty or a fine of up to PLN 10,000 (art. 28 para. 4).
  • The act has no penalty for the mere lack of a separator, but breaching the bans in art. 9 paras 1 and 2 carries the same penalty (art. 28 para. 4a), and after a 20-day notice the undertaking may close the connection (art. 8).
  • Before buying, ask the water utility in writing which device and indicators it requires; the 5 m distance from the former § 38 of the technical conditions has an unclear status today (act deemed repealed from 21.09.2026), so settle it with the designer.
  • The 2016 regulation: wastewater temperature up to 35°C, pH 6.5 to 9.5, and in the annex an indicator of petroleum-ether-extractable substances of 100 mg/l (the undertaking may set other values).
  • Separator grease is waste: code 19 08 09 for edible fats only, 19 08 10* when mixed with other oils; used fryer oil is a separate code, 20 01 25.
  • Keep the paperwork: the contract, service records, transfer cards and the collector's BDO number; calculate the annual cost with the formula, and the sample numbers in the text are invented, not a price list.

A few words that show up in this text

Explained in plain language — you do not need to know the trade to read on.

lead
An enquiry from someone still considering a purchase — not a client yet.
dashboard
A single screen showing the most important numbers instead of multiple reports.

A grease separator in a restaurant in Poland does not come from a single provision that orders you to install one. The requirement grows out of the duty to pretreat industrial wastewater (art. 10 of the act on collective water supply and wastewater disposal), out of the terms of the written contract with the water utility, and out of technical standards. The grease you collect is waste (it has its own code in the waste catalogue), so it must be handed over to an entity authorised to manage waste.

This is an educational guide, not legal advice and not an installation design. We quote the rules from texts published in the Journal of Laws (Dziennik Ustaw, Dz.U.): the act on collective water supply in its 2024 consolidated text, the 2016 regulation on discharging wastewater, and the 2020 waste catalogue, all read from the Sejm's ELI database. Information about Warsaw comes from the MPWiK website. All sources were opened on 19.10.2026. Where something is our assessment rather than the text of a rule, we say so plainly: interpretation. Where we could not establish something, we write "we did not establish". The limit values for your premises are written into the contract by your own water utility, so the last word always belongs to it. Quotations are our translation; the originals are in Polish.

Does the law say outright that you must install a separator?

In short: we did not find, in the act or in the regulation, a sentence such as "every restaurant must have a grease separator". What exists instead is a chain of duties that in practice lead to the same device.

The key provision is art. 10 point 2 of the act of 7 June 2001 on collective water supply and collective wastewater disposal (ustawa o zbiorowym zaopatrzeniu w wode i zbiorowym odprowadzaniu sciekow). It opens with the words: "A supplier of industrial wastewater discharged into sewerage facilities is obliged to:", and point 2 lists "installing the necessary devices that pretreat industrial wastewater and operating those devices properly". A grease separator is exactly such a pretreatment device. The act also counts "devices that pretreat and treat wastewater" among sewerage facilities (art. 2 point 14).

Then there is the implementing regulation (art. 11 of the act authorises the minister to issue it). Its § 4 says that installing the necessary pretreatment devices should follow "the best available techniques". The Warsaw water utility MPWiK repeats the same sentence on its page for industrial-wastewater customers.

Conclusion (interpretation): if the water utility treats the wastewater from your kitchen as industrial, or writes a grease pretreatment condition into the contract, a separator becomes an obligation for you. If there is no such condition, you are still responsible for keeping grease from damaging the network, but how you hold it back is a matter to agree with the utility. So before buying a device, ask the operator in writing what exactly it requires.

Domestic or industrial wastewater: where the line is

The act divides wastewater into two groups, and that decision determines whether art. 10 applies to you at all.

Art. 2 point 9 defines domestic wastewater: "wastewater from residential buildings, collective housing and public-utility buildings, arising from human metabolism or the running of households, and wastewater of similar composition coming from those buildings".

Art. 2 point 11 defines industrial wastewater as "wastewater that is neither domestic wastewater nor rain or melt water resulting from precipitation, arising in connection with the commercial, industrial, storage, transport or service activity carried on by a business", discharged through that business's own sewerage facilities.

A restaurant carries on a service and commercial activity, but the wastewater from guest toilets is typically domestic. Wastewater from the kitchen, the dishwashing area and the frying station has a different composition: a lot of grease, food scraps, cleaning agents and high temperature. Whether that is wastewater "of similar composition" to household water or already industrial, the act does not settle with the word "restaurant". In practice the decision rests with the water utility's position, recorded in the contract or in the conditions for discharging wastewater (interpretation).

What this means for a venue owner:

  • a small bar with one dishwasher may face different requirements from a kitchen with deep fryers and high-volume production,
  • a change in the kitchen's profile (adding deep frying, a takeaway kitchen, a dark kitchen) is a reason to go back to the operator and ask whether the existing conditions are still enough.

The contract with the water utility, step by step

The basis is art. 6 para. 1 of the act: "Water is supplied or wastewater is discharged on the basis of a written contract for water supply or wastewater discharge concluded between the water and sewerage undertaking and the customer." The contract may be concluded with a person who holds a legal title to use the property (art. 6 para. 4). Where a building has many units, the owner or manager concludes the contract with the undertaking (para. 5), and at their request the undertaking also concludes one with the person using a unit, if the conditions of para. 6 are met (among them, water meters at the draw-off points). So if you rent your premises, check who is the party to the water contract and what your lease says about it. See the article on the restaurant lease agreement.

Among other things, the contract contains (art. 6 para. 3) "the procedures and conditions for inspecting water supply facilities and sewerage facilities", as well as its term and the parties' liability. This is where the undertaking can write its requirements for kitchen wastewater.

A practical order of action when opening or changing premises:

  1. Establish who is the party to the contract. Check whether the wastewater discharge contract for the premises is in the name of the building owner, the owners' association or you. Ask for a copy.
  2. Describe your operation. The type of kitchen, the equipment (fryers, pans, dishwasher, dish trolley), the number of meals, opening hours. The operator needs this to assess the wastewater's composition.
  3. Ask about requirements for kitchen wastewater. Write an email with concrete questions: is a grease pretreatment device required, which pollution indicators apply, must the wastewater be tested periodically, does the operator want to approve the design.
  4. Keep the reply. Written conditions are your proof that the installation meets the undertaking's expectations.
  5. Only then buy and install. Sizing is done by the designer or supplier according to the standard, and the installation spot is agreed with the building owner (see below).
  6. Build inspection into your routine. The undertaking has the right to enter and check wastewater quality (art. 7 point 4), and you must give access to inspection points "at any time" (art. 10 point 3).

Warsaw: MPWiK and the municipal regulations

In Warsaw wastewater is taken by the Municipal Water and Sewerage Company (MPWiK). On its page for service customers, in the section on obligations when discharging industrial wastewater, MPWiK quotes art. 9 para. 2 and art. 10 of the act and the 2016 regulation, and repeats the sentence about "the best available techniques". The page does not mention grease separators by name (we did not find such a sentence), so the assessment of a specific venue is an individual matter. The contact details given on the page: helpline +48 22 445 50 00, email dok@mpwik.com.pl, head office at pl. Starynkiewicza 5 (as of a copy of the page from 20.01.2026, check the current details).

The second document is the regulations on water supply and wastewater discharge (regulamin). Under art. 19 para. 4 of the act it is a local law. For Warsaw, MPWiK points to resolution No. XV/375/2019 of the Council of the Capital City of Warsaw of 4 July 2019. The file with its text that we managed to open is a scan without a text layer, so we did not establish what it says about grease separators. Read the regulations in the version published in the Official Journal of the Mazovian Voivodeship before you start the design, and if in doubt ask MPWiK about the current legal position.

What must not go into the sewer

Regardless of a separator, the bans in art. 9 para. 2 of the act apply. They list, among other things, "solid waste that may reduce the capacity of sewer pipes" (including gravel, sand, glass, yeast, textiles and fibres, even if shredded) and "liquid waste that does not mix with water", as well as flammable substances with a low flash point. The illustrative list begins with the words "in particular", so it is not closed.

Grease does not appear in these provisions by name, but it is a liquid that does not mix with water and that solidifies on cooling and reduces pipe capacity (interpretation).

In the kitchen this means a few rules worth writing down and hanging by the sink:

  • used fryer oil does not go down the sink, it goes into a separate container (it is a separate waste, see below),
  • plate scrapings are collected dry before washing,
  • diluting wastewater with water in order to "fit" the limits is forbidden: § 7 of the regulation states that industrial wastewater may not be diluted with water "in order to achieve permissible values of pollution indicators",
  • drain cleaners and detergents are used according to the product data sheet, not "by eye".

The standard, temperature and indicators

The 2016 regulation (consolidated text, Dz.U. 2016 item 1757) sets out the requirements for wastewater discharged into the sewer. From the kitchen's point of view three things matter most.

Temperature and pH. Under § 8 point 3, the temperature of the wastewater does not exceed 35°C, and the pH lies between 6.5 and 9.5. Hot water from a commercial dishwasher can exceed this, so the designer checks that the wastewater cools before the separator.

Indicators in annex no. 2. The regulation contains a table of permissible values. Item 42 lists "substances extractable with petroleum ether" at 100 mg/l, and item 41 lists "petroleum hydrocarbons" at 15 mg/l (interpretation: the first indicator relates, among other things, to fats and oils, but the text does not tie it to the word "restaurant").

10%
The undertaking sets the range of indicators and their values depending on the specifics of the wastewater (§ 12) and may set lower values (§ 13, where industrial wastewater is more than 10% of the municipal wastewater reaching the treatment plant) or higher ones (§ 14, where it is less than 10%), so the contract may show numbers different from the table.

Measurements. The values from the annex should be met in a 24-hour average sample, and sampling and measurement are carried out by the industrial wastewater supplier "no less often than twice a year" (§ 10 paras 2 and 3); for pH and temperature, single samples count. Whether your venue is treated as an industrial wastewater supplier and subject to such monitoring depends on the undertaking's position and the contract (interpretation).

The PN-EN 1825 standard. Trade websites refer to PN-EN 1825 (part 1 covers design principles, part 2 covers selecting the nominal size, installation and operation). We have not read the standard itself, because it is paid, and we do not rely on its content. The practical point: the size of a separator depends on the nominal flow, that is, on which appliances there are and how much water arrives at peak. "Bigger is always better" does not work: an oversized separator with a small flow is more expensive to empty, and an undersized one will not hold back the grease.

Where to put the separator and what about building rules

The installation spot is often the most expensive decision. A separator can stand inside the building (small units under the sink or by the dishwashing area) or in the ground in front of the building (larger ones, with an access hatch for cleaning). Several threads come with this.

Distances. The 5 m rule known from practice comes from § 38 of the regulation on technical conditions that buildings and their location must meet (consolidated text: Dz.U. 2022 item 1225). Its wording was: "The distance of mud settlers, mineral oil and grease separators, wastewater neutralisers and other similar tanks from openable windows and external doors of rooms intended for people to stay in should be at least 5 m, unless separate provisions state otherwise." A note on status: in the Sejm's ELI database (as of 19.10.2026) this act has the status "deemed repealed" from 21 September 2026 (the act of 19 July 2019 on ensuring accessibility for persons with special needs, Dz.U. 2019 item 1696, is cited). We did not establish which provision replaces it or how the authorities now apply the 5 m distance, so we do not present § 38 as being in force. It is a rule of the former act; how to apply it now, settle with the designer or a building expert before choosing the spot.

Questions for the designer. Trade design guides point to several things worth asking about (this is practice, not a rule we quote here): an inspection chamber for taking samples after the separator, an alarm for grease and sludge level, ventilation of the room with the separator, and cooling hot wastewater before the device (compare the 35°C limit in § 8 of the wastewater regulation).

Access. A separator has to be emptied regularly, so the collection vehicle and hose must be able to reach it. If it is in a yard closed by a gate, check who has the key and when the manager opens the gate.

Smells and hygiene. A device inside the kitchen must be sealed and cleaned away from food products. We covered the sanitary requirements for the premises in the article on food safety approval and HACCP; settle the specific rules for the separator with the designer and the competent authorities.

Ownership and lease. If you rent the premises, agree in writing who pays for installation and servicing and whether the device stays when you move out.

Emptying and collecting grease: waste code 19 08 09

The grease that is retained is waste. The regulation of the Minister of Climate of 2 January 2020 on the waste catalogue (Dz.U. 2020 item 10) contains, in group 19 08, the entry "19 08 09 Grease and oil mixtures from oil/water separation containing only edible oils and fats". Next to it is the entry "19 08 10* Grease and oil mixtures from oil/water separation other than those mentioned in 19 08 09". The asterisk means hazardous waste.

The catalogue divides waste by source (§ 2): group 19 is waste from waste management facilities, from wastewater treatment plants and from water preparation, and subgroup 19 08 is titled "Wastes from wastewater treatment plants not otherwise specified". The regulation does not say outright which code a restaurant's separator grease has, so assigning it entry 19 08 09 is our interpretation based on the wording of the entry. The code in documents is usually given by the waste producer, that is, the venue that operates the separator, and in practice it is confirmed by the collector.

The distinction matters in practice. If only kitchen grease reaches the separator, entry 19 08 09 matches its origin. If the wastewater is mixed with mineral oils (for example from mopping floors with petroleum-based agents or from washing mechanical equipment), the content may become 19 08 10* (interpretation: ask the collecting company how it classifies the content of your separator).

A separate entry in the same catalogue is "20 01 25 Edible oil and fat" (group 20: municipal waste including separately collected fractions). Used fryer oil, which the venue produces in the kitchen rather than in the separator, is usually recorded under this code (interpretation). It follows a different route from separator grease, so do not pour it into the separator to "save on collection".

What to do in practice:

  • Find an authorised collector. A company collecting waste from separators should normally be entered in the BDO register and issue waste transfer documents (details are in the article on BDO; we do not discuss the waste act here). Ask for their BDO number and a sample transfer card.
  • Set a schedule. The emptying frequency depends on the size of the device and the intensity of the kitchen. We did not establish a single binding number of days, so ask the separator supplier and the water operator whether the contract sets its own interval.
  • Collect the paperwork. Transfer cards, emptying confirmations and service records are proof that the separator is "properly operated" (art. 10 point 2) when an inspection comes.

BDO and records: without duplication

The record-keeping duties for kitchen waste (registration, transfer cards, reports) are described in a separate article: waste register and BDO for restaurants in Poland. Here remember two things. First, you add separator waste to your records together with the other waste from the premises. Second, the collector confirms the takeover in the system, so without their BDO number and document you have no proof of transfer. We do not give penalties from the waste act in this text, because we did not verify them in this work: check them in the BDO article or in the current text of the act.

Less scrapings in the sink start with smaller food losses: see food waste in food service and FIFO in restaurants.

Penalties and consequences

The act on collective water supply provides for two kinds of consequences: criminal sanctions and actions by the undertaking.

Penalties in art. 28. Para. 4: "Whoever discharges wastewater into sewerage facilities without first concluding the contract referred to in art. 6 para. 1 is liable to a penalty of restriction of liberty or a fine of up to PLN 10,000." Para. 4a extends this penalty to whoever "fails to comply with the bans referred to in art. 9 paras 1 and 2". On conviction the court may order a payment to the undertaking (para. 5, PLN 1,000 for each month of discharging wastewater without a contract). Whoever refuses to admit the undertaking's representative for the activities in art. 7 (including checking wastewater quality) is liable to a fine of up to PLN 5,000 (art. 28 para. 2 point 2 in conjunction with para. 1).

Note what this provision does not contain: there is no penalty "for the lack of a separator" as such. There are penalties for wastewater without a contract, for breaching the bans in art. 9, and for obstructing inspection. But having no separator, with grease overflowing into the network, can lead to a breach of the ban in art. 9 para. 2 or of the contract terms (interpretation).

Actions by the undertaking. Art. 8 para. 1 point 3 allows the undertaking to "cut off the water supply or close the sewer connection" if the quality of the discharged wastewater does not meet the requirements laid down by law, or if deliberate damage to or bypassing of a measuring device is found. The undertaking notifies its intention to, among others, the service customer, the mayor of the municipality and the sanitary inspector "at least 20 days before the planned date" (art. 8 para. 3), so it is not an overnight action, but it is real for premises that ignore warnings.

Costs: a worked example

We did not find a reliable, public price list for collecting grease from a separator, so we do not give "market rates". Instead we show how to calculate the annual cost, so that you can insert your own numbers from quotes.

The formula for the annual running cost:

annual cost = (number of collections per year × price of one collection) + servicing and inspection + any wastewater tests

An illustrative example: the numbers are invented for the calculation, they are not market prices or any company's price list:

ItemAssumption (example)Result (example)
Grease collections12 times a year at PLN 400 netPLN 4,800
Servicing and cleaning the chamberonce a year, PLN 600 netPLN 600
Wastewater teststwice a year at PLN 300 netPLN 600
TotalPLN 6,000 a year

With these assumptions the monthly cost is PLN 500, which at 3,000 meals a month is about 17 groszy per meal. This is not a forecast for your venue, only a method of calculation. Multiply your own numbers and add the result to your fixed costs. For the break-even calculation the article on the restaurant break-even point will help, and for comparison with other utilities restaurant energy cost per cover.

The cost of purchase and installation depends on size, location and groundworks. Collect at least two written quotes.

Owner's checklist

If you answer "I don't know" to any item, it is this week's task.

  1. I have a copy of the water utility contract for wastewater discharge for my premises and I know who is the party.
  2. I asked the operator in writing whether it requires a grease pretreatment device and which indicators apply.
  3. In Warsaw I read the regulations on water supply and wastewater discharge in the version from the Official Journal.
  4. I have the supplier's sizing based on flow, not "by eye".
  5. I agreed with the designer the location and the distances from windows and doors (the former § 38 of the technical conditions, 5 m, has an unclear status today) and the access for the collection vehicle.
  6. I have a contract with the grease collection company, its BDO number and a sample transfer card.
  7. I know which waste code the collector assigns (19 08 09 or another) and I have it in my records.
  8. I have an emptying schedule and a calendar entry with a responsible person.
  9. Staff know that used oil goes separately and that scrapings are collected dry before washing.
  10. In case of an inspection I have the contract, the service records and the collection confirmations at hand.

Where AURA fits in all this

AURA is in preparation: today it does not keep waste records and does not monitor the separator. How a dashboard with deadlines and documents could look is shown by the demo dashboard (a showcase version on sample data). It is a demonstration, not a feature you can buy, so for now record emptying dates in a calendar or a spreadsheet.

Frequently asked questions

Does every restaurant have to have a grease separator?

We did not find a provision that says so outright. The duty to pretreat industrial wastewater comes from art. 10 point 2 of the act, and the conditions for a specific venue are set by the water utility in the contract. In practice a kitchen with frying almost always gets such requirements, but ask the operator about them in writing.

Does a sandwich and coffee bar need a separator too?

It depends on the composition of the wastewater and on the operator's position (interpretation). A cafe without frying and without large-scale production may have wastewater close to domestic, while a venue with fryers and a commercial dishwasher probably does not. Do not assume the answer: ask the water utility, describing your equipment and number of meals.

What are the penalties for having no contract with the water utility?

Art. 28 para. 4 of the act provides for restriction of liberty or a fine of up to PLN 10,000 for whoever discharges wastewater into sewerage facilities without a prior contract under art. 6 para. 1. In addition, the undertaking may in certain situations close the connection (art. 8).

Who collects the grease from the separator and what is its code?

It is collected by a company authorised to manage waste, entered in BDO, which issues a transfer document. In the waste catalogue, grease from oil/water separation containing only edible oils and fats has code 19 08 09. When the content is contaminated with other oils it may be 19 08 10*. Confirm the code with the collector.

How often does a separator need to be emptied?

We did not establish a single interval from the rules that would cover every venue. The frequency depends on the size of the device, the intensity of the kitchen and the requirements in the water contract or in the manufacturer's manual. Write the proven interval in your calendar and keep the confirmations, because they show that the device is properly operated.

Can I pour used fryer oil into the separator?

You should not. Used edible oil has a separate code in the waste catalogue (20 01 25) and a separate collection route, and pouring it into the sewer may breach the bans in art. 9 para. 2 (interpretation). Keep it in a sealed container and hand it to the collector, ideally with a document.

Can bio-preparations replace a grease separator?

We did not find a provision that would allow such a replacement, nor one that would rule it out outright. Since art. 10 point 2 speaks of "pretreatment devices" and the conditions are set by the operator, ask the water utility in writing whether it accepts such a solution at all (interpretation).

Where do I check the requirements in Warsaw?

Start with the MPWiK Warsaw page on the obligations of industrial wastewater customers and with the regulations on water supply and wastewater discharge adopted by the Council of the Capital City of Warsaw (resolution No. XV/375/2019). Also ask MPWiK by email or through the helpline. Keep the reply, because the wording of the contract takes precedence for your venue over general descriptions found on the internet.

Sources

  • Act of 7 June 2001 on collective water supply and collective wastewater disposal, consolidated text Dz.U. 2024 item 757 (art. 2, 6, 7, 8, 9, 10, 11, 19, 28), api.sejm.gov.pl/eli/acts/DU/2024/757, opened 19.10.2026. The amendment of 13.03.2026 (Dz.U. 2026 item 605) changes in art. 8 para. 3 only the name of the authority (the state county sanitary inspector); we found no changes in art. 6, 7, 9, 10 and 28, but check the current text before deciding.
  • Regulation of the Minister of Construction of 14 July 2006 on the manner of performing the duties of industrial wastewater suppliers and the conditions for discharging wastewater into sewerage facilities, consolidated text Dz.U. 2016 item 1757, api.sejm.gov.pl/eli/acts/DU/2016/1757, opened 19.10.2026.
  • Regulation of the Minister of Climate of 2 January 2020 on the waste catalogue, Dz.U. 2020 item 10, api.sejm.gov.pl/eli/acts/DU/2020/10, opened 19.10.2026.
  • Regulation on the technical conditions that buildings and their location must meet, consolidated text Dz.U. 2022 item 1225 (§ 38), api.sejm.gov.pl; status in ELI: "deemed repealed" from 21.09.2026; cited solely as a former rule, opened 19.10.2026.
  • MPWiK Warsaw, "Obligations of MPWiK service customers when discharging industrial wastewater", mpwik.com.pl (read from a copy of 20.01.2026), opened 19.10.2026.
  • MPWiK Warsaw, "Legal acts" page (resolution No. XV/375/2019 of the Council of the Capital City of Warsaw of 4 July 2019, Dz. Urz. Woj. Maz. of 2019 item 9019), mpwik.com.pl (copy from 2026), opened 19.10.2026. The text of the regulations was not read.
  • A survey of Polish trade websites on separators (wodkangaz.com, duer.pl, wodkaneko.pl) used only as background; we take no claims about rules or prices from them, opened 19.10.2026.

Related services

In this section

Let us look at your numbers

Tell us how enquiries are handled today — how many there are, who picks them up, where they get lost. Aura walks the process with you and shows what can be taken off a person, and what is better left alone.

Talk to Aura

The home page with Aura opens. Give a company name — she looks at it in public data and shows what a client sees. No promises of a result.

Prefer to write? marketing@auraglobal-merchants.com

Next step

Let us check whether Aura fits your place

We do not take everyone: first we look at your processes, sales and current systems and tell you honestly whether it makes sense for us to come in. A few questions, about five minutes.

Take the assessment →